Adjust the distance according to the length of the toothbrush (Adjust the blut block). The distance is 2mm longer than the length of the toothbrush.
Adjust the width of the baffle according to the length of the toothbrush handle.
Loosen the screw 1, then adjust screw 2 to adjust the distance between the baffles 3. The distance is 2mm longer than the length of the toothbrush. Then tighten the screw 1.
The position of the turning device needs to be adjusted according to the length of the toothbrush.
Loosen screw 1 and adjust the upper compression mechanism.
Loosen screw 2 and adjust screw 3 to change the position of the turning device to the middle position of the toothbrush handle.
Tighten the screw 2.
Loosen the screw3, adjust block1 and block2 according to the bending degree of the toothbrush handle.
Loosen the screw1, adjust the lift block according to the bending degree of the toothbrush handle.
Adjust the block1 and block2 according to the bending degree of the toothbrush handle.
Rotate the handwheel 1 to move the stamping head to the left or to the right
Rotate the handwheel 2 to move the stamping head to the up or to the down